Your hotel
Every space in your hotel, monitored and understood.
From the plant room to the guest rooms: what we monitor, what ConnectIA detects and what gets logged.
In every space, with your current equipment or with wireless sensors.
Guest rooms ready before every arrival.
Every room prepares itself before arrival and goes into standby after checkout. Before assigning it, you know it meets its comfort settings.
What we monitor
- Actual temperature and setpoint
- Windows and doors
- Presence
- HVAC consumption
- Booking status (PMS)
What ConnectIA detects
- Rooms that do not reach their temperature
- HVAC running with the window open
- HVAC on in empty rooms
What gets logged
- Comfort history by room
- Incidents and who resolved them
What it connects to
- KNX and existing in-room systems
- Wireless thermostats and sensors
- Your PMS
Wireless devices or existing technology.Do I need building works?
No. With KNX we connect to what is already there; without KNX, we fit wireless thermostats and sensors with no works.
Is it a separate product?
No. It is a MaindHotel module, activated on the same platform as the rest of the hotel.
How is it priced?
Per room. We detail it in the proposal according to the number of rooms and the equipment.
Plant rooms that warn you before they fail.
DHW, boilers, heat pumps, chillers and pressure booster sets: how they run, how much they consume and when they move outside normal.
What we monitor
- DHW temperatures (flow, return and tanks)
- Circuit pressures
- Tank and cistern levels
- Equipment consumption
What ConnectIA detects
- DHW below its reference temperature
- Pressure or level out of range
- Abnormal consumption for the day's conditions
What gets logged
- Temperatures for Legionella prevention
- Deviations with their duration and correction
What it connects to
- PLCs and controllers (Modbus, BACnet)
- Wireless temperature, level and pressure probes
- Energy meters
Wireless devices or existing technology.Kitchens with refrigeration always watched.
Cold rooms, freezers and display units watched day and night. ConnectIA tells a defrost cycle from a real breakdown and only alerts when the product is at risk.
What we monitor
- Temperature of cold rooms, freezers and display units
- Door openings
- Defrost cycles
What ConnectIA detects
- Real breakdowns, not defrost cycles
- Doors left open
- Temperatures rising outside their usual cycle
What gets logged
- Temperature log for HACCP
- Incidents with their cause and correction
What it connects to
- Wireless temperature and door sensors
- Existing refrigeration controllers
Wireless devices or existing technology.Pools and spa with water always in range.
Water quality, temperature and filtration, with the health log up to date and the pool contractor alerted in time.
What we monitor
- Chlorine and pH
- Water temperature
- Pool and tank levels
- Filtration status
What ConnectIA detects
- Values outside the health range
- Filtration failures
- Trends that anticipate a problem
What gets logged
- Pool health log
- External contractor interventions
What it connects to
- Existing chlorine and pH controllers
- Wireless probes
Wireless devices or existing technology.Common areas as guests experience them.
Lobby, restaurant, function rooms and gym: air, noise and temperature as guests feel them, and their water and energy use, including outside opening hours.
What we monitor
- Air quality (CO₂) and noise
- Temperature and humidity
- Water and energy consumption
- Leaks
What ConnectIA detects
- Function rooms with stuffy air
- Consumption outside opening hours
- Water leaks
What gets logged
- Comfort history by area
- Consumption by area and by time slot
What it connects to
- Wireless air, noise and leak sensors
- Water and energy meters
- Existing HVAC systems
Wireless devices or existing technology.Across the whole hotel
One platform for every space.
Everything you connect in each space comes together in MaindHotel.
ConnectIA understands the whole picture and mobilizes whoever needs to act.